Page 9 of 9. There were 161 matching component found.
Lignum ID-№ Base structure Construction height Values of airborne sound insulation
Graphic Paneling Weight
Origin of sound insulation values U-value

D1261

Stud 288 mm 46 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 1st layer: Wood fiber facade insulation board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Cellulose: Loose; not monitored
Bond: Rigid, execution of the prior art.
Sheathed rightside 1st layer: Biofaser HB.HLA 2 Funderplan
Battens / profiles: Wood lath b=75mm
Cavity dampening: Wood fiber board ≥ 180kg/m³
Covering rightside1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface rightside: Glued joints/smoothed

Compact facade 66 kg/m2 -1 dB
Verified calculation ≈ 0.165 W/m2K -6 dB